WNS series gas-fired (oil-fired) steam boiler

WNS series gas-fired (oil-fired) steam boiler

Product thermal capacity:1-20 t/h

Working pressure: 0.7-2 Mpa

Read More
DZL series coal-fired steam boiler

DZL series coal-fired steam boiler

Product thermal capacity: 2 – 20t/h

Working pressure: 1.0-2.5 MPA

Read More
DHL series coal-fired steam boiler

DHL series coal-fired steam boiler

Product thermal capacity:20-110 t/h

Working pressure: 1.25-5.3 Mpa

Read More
SZS series gas-fired (oil-fired) steam boiler

SZS series gas-fired (oil-fired) steam boiler

Product thermal capacity:20-110 t/h

Working pressure: 1.25-5.3 Mpa

Read More
SZL series coal-fired steam boiler

SZL series coal-fired steam boiler

Product thermal capacity:4-35 t/h

Working pressure: 1.0-2.5 MPA

Read More
CFB (circulating fluidized bed) coal-fired steam boiler

CFB (circulating fluidized bed) coal-fired steam boiler

Outlet temperature:194-485 ℃

Product thermal capacity:35-75 t/h

Read More
YLW series coal-fired/biomass-fired thermal fluid heater

YLW series coal-fired/biomass-fired thermal fluid heater

Product thermal capacity:1400-29000 KW

Working pressure: 0.8-1.0 MPA

Read More
YQ(Y)L series gas-fired/oil-fired thermal fluid heater

YQ(Y)L series gas-fired/oil-fired thermal fluid heater

Product thermal capacity:7000-29000 KW

Working pressure: 0.8-1.0 MPA

Read More
YQ(Y)W series gas-fired/oil-fired horizontal thermal oil heater

YQ(Y)W series gas-fired/oil-fired horizontal thermal oil heater

Product thermal capacity:700-14000 KW

Working pressure: 0.8-1.0 MPA

Read More
RYQ series molten salt heater

RYQ series molten salt heater

Product thermal capacity:20-110 t/h

Working pressure: 1.25-5.3 Mpa

Read More

    • what is boiler water ph? and why so maintained? - quora

      What is boiler water PH? And why so maintained? - Quora

      > Natural water is usually between 6.5 and 7.5 pH. A common recommendation is to maintain boiler water at 8.5 pH.Acidic water is corrosive. Alkalinic water is more prone to scaling.Alkalinity is a measure of the bicarbonate (HCO3), carbonate (CO3

      Read More
    • ph treatment | cleanboiler.org

      pH Treatment | CleanBoiler.org

      Natural water is usually between 6.5 and 7.5 pH. A common recommendation is to maintain boiler water at 8.5 pH. Acidic water is corrosive. Alkalinic water is more prone to scaling. Alkalinity is a measure of the bicarbonate (HCO3), carbonate (CO3) and hydroxyl (OH) ions in the water. pH and alkalinity ratings are NOT the same and are NOT

      Read More
    • the importance of ph in steam-boiler water - heating help

      The importance of pH in steam-boiler water - Heating Help

      That oxygen comes out of solution as the water boils, and it can eat holes in the boiler, right at the boiler’s waterline. If you decide to feed with hot water instead of cold water, the minerals in the water will come out of solution on the automatic water-feeder’s seat, and that can cause a flood, especially if it’s a one-pipe-steam system.

      Read More
    • water handbook - preboiler & industrial boiler corrosion

      Water Handbook - Preboiler & Industrial Boiler Corrosion

      The pH or alkalinity level maintained in a boiler system depends on many factors, such as sys-tem pressure, system metals, feedwater quality, and type of chemical treatment applied. The corrosion rate of carbon steel at feedwater temperatures approaches a minimum value …

      Read More
    • high pressure boilers flashcards and study sets | quizlet

      high pressure boilers Flashcards and Study Sets | Quizlet

      Learn high pressure boilers with free interactive flashcards. Choose from 500 different sets of high pressure boilers flashcards on Quizlet.

      Read More
    • boiler pressure - an overview | sciencedirect topics

      Boiler Pressure - an overview | ScienceDirect Topics

      Marcelo Junqueira, in Bioenergy - Realizing the Potential, 2005. Phase 1 - 2003. A high efficiency pressure boiler providing 65 bar at 200 ton of steam per hour and 510°C (the first in the sugar industry in Brazil) is installed. This implies a significant reduction of the amount of bagasse used per ton of steam generated. Two new contra pressure-type turbo generators at 15 MW each and two new

      Read More
    • draft boiler/feedwater guidelines

      DRAFT BOILER/FEEDWATER GUIDELINES

      the boiler water should be maintained at pH 11. This may require an addition of alkali if the water is not soft. Secondly, a chemical called a sludge conditioner can be added to treat the solids so that they drop out (precipitate). Finally, these treated solids must be removed from the boiler by blowoff.

      Read More
    • types of high pressure boilers | sciencing

      Types of High Pressure Boilers | Sciencing

      This pressure is measured in terms of pounds per square inch or “psi,” and gauge pressure is expressed as “psig.” The National Fire Prevention Association and federal standards define a Type II steam boiler as one that produces high-pressure steam between 16 and 150 psig. A Type III steam boiler produces steam between 151 and 350 psig.

      Read More
    • chemical regime in water quality management of high

      Chemical Regime in Water Quality Management of High

      pH at 25oC for Non-Cu alloy pre boiler system plants has to be between 9.0-9.4 for all pressure ranges. Dissolved Oxygen has to be maintained below 0.007 ppm for pressure range 61-165 kg/cm2 and 0.005 ppm for a pressure range 166-205 kg/cm2.

      Read More
    • the international association for the properties of water

      The International Association for the Properties of Water

      boiler drum pressure boiler water dissolved solids concentrations, and boiler water pH and interactions between the species present. Thus, information is required on the volatility of the salts and their corresponding acids and bases likely to be present in boiler water, such as …

      Read More
    • (pdf) using of congruent phosphate as equilibrium

      (PDF) Using of congruent phosphate as equilibrium

      Tremaine, P.R., Gray, L. and Stodola, J., Sodium phosphate chemistry under high pressure utility drum boiler conditions, Canadian Electrical Association Report 913 G730(1992). Water side corrosion

      Read More
    • difference between low- and high-pressure boilers | hunker

      Difference Between Low- and High-Pressure Boilers | Hunker

      A boiler is an appliance designed to heat water and produce energy. The heat is applied to water in an enclosed container before being distributed throughout the system. The major difference between a low-pressure and a high-pressure boiler is the amount of pressure per square inch and pounds per square inch gauge that the boiler produces.

      Read More
    • buildings - high pressure boiler inspections

      Buildings - High Pressure Boiler Inspections

      High Pressure Boiler Inspections. Owners must hire a qualified boiler inspector employed by an authorized insurance company to perform annual high pressure boiler inspections. The Department will not be conducting these inspections for the upcoming cycle. Annual Inspection Cycle. January 1 to December 31. Inspections

      Read More
    • asme - international boiler and pressure vessel code

      ASME - International Boiler and Pressure Vessel Code

        1. Power Boilers. This Section provides requirements for all methods of construction of power, …

          Standard Specification for Seamless Carbon Steel Boiler

          1.1 This specification 2 covers minimum-wall-thickness, seamless carbon steel boiler and superheater tubes for high-pressure service. 1.2 The tubing sizes and thicknesses usually furnished to this specification are 1 / 2 in. to 7 in. [12.7 to 177.8 mm] outside diameter and 0.085 to 1.000 in. [2.2 to 25.4 mm], inclusive, in minimum wall thickness.

          Read More
        2. high pressure boilers: features and advantages ~ me mechanical

          High Pressure Boilers: Features and Advantages ~ ME Mechanical

          Oct 27, 2016 · A boiler is called a high-pressure boiler when it operates with a steam pressure above 80 bars. The high-pressure boilers are widely used for power generation in thermal power plants. In a high-pressure boiler, if the feed-water pressure increases, the saturation temperature of water rises and the latent heat of vaporization decreases.

          Read More
        3. general engineering data - complete boiler room solutions

          General Engineering Data - Complete Boiler Room Solutions

          the nominal pipe size. The intersection will give the pressure drop in psi per 100 feet of equivalent pipe length. For example, a typical No. 2 fuel oil has a viscosity 40 SSU. A 500 hp boiler requires up to 115 gallons per hour of No. 2 oil. Using Table 2, and specifying a 1-inch nominal pipe size, gives 0.1 psi pressure drop at 100 gph, and 0

          Read More
        4. boiler hydrostatic testing procedure - boilersinfo

          Boiler Hydrostatic testing procedure - Boilersinfo

          This procedure defines the requirement and procedure of hydrostatic testing of the boiler pressure parts after completing the assembly of all the boiler high pressure and temperature components. Hydrostatic testing Objective Hydrostatic testing in the boiler is carried out to check the following: Leakages in the boiler pressure parts (Tubes, headers and Pipes).

          Read More
        5. ph value in steam boiler drum

          ph value in steam boiler drum

          Ph And Phosphate Concentration In Bfw And Steam Drum - posted in Industrial Professionals: Boiler feed water (BFW) pH is to be maintained in the range of 8.0 to 9.5(guidelines) where as in steam drum pH maintaining guidelines is in the range of 9.5 to 11.0.

          Read More
        6. high pressure boiler operating engineer license - nyc business

          High Pressure Boiler Operating Engineer License - NYC Business

          A High Pressure Boiler Engineer License (Stationary and Portable) is required to operate high-pressure boilers in New York City. Please contact the Department of Buildings for more information.